GRT-20 | 2-3/4” Gamma Ray Pulse Tool

The DSS 2 3/4” Gamma Ray pulse Tool (GRT) measures the gamma radiation level of the formation derived from natural isotopes. It can be used as a depth correlation device between cased and open holes. This tool is comprised of a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The GRT-01 outputs 25 µs pulses in response to gamma radiation within the well.

Share on linkedin
Share on facebook

Applications

Gamma radiation measurements
Depth correlation
Reservoir delineation

Features

Rated for high-temperature and high-pressure environments
Scintillation crystal combined with a photomultiplier
Compatible with most surface systems
Runs on all standard wirelines
Power and telemetry are connected from the top to bottom of the tool
Can be run by itself, or combined with most analog tools
Electronic design verified for 1 hour operation at 415°F to ensure reliability
Easy to service and maintain

Specifications

Tool Operating Voltage 90-150 VDC Tool Length (make-up) 66.68 cm (26.25 in)
Tool Operating Current 20-25 mA Tool Length (Shipping) 74.93 cm (29.5 in)
Output Pulses Amplitude Negative 7.5 VDC Tool Weight 11.6 Kg (28 Lb)
Output Pulses Width 25 µS Measurement Point from Top of Tool 43.35 cm (17.07 in)
Max. Pressure 172.4 Mpa (25,000 PSI) Borehole Fluids Oil – Fresh Water – Brine
Max. Temperature 204°C (400°F) Top End Connector Contact Socket Go Female
Tool Diameter – OD 69.85 mm(2-3/4 in) Bottom End Connector Contact Pin Go Male

 

I'd like to get a quote on GRT-20 | 2-3/4” Gamma Ray Pulse Tool

Products related to GRT-20 | 2-3/4” Gamma Ray Pulse Tool

TTP-11 | 1-11/16″ Temperature Pulse Tool

TTP-11 | 1-11/16" Temperature Pulse Tool

The 1-11/16” Temperature Pulse Tool (TTP-11) measures borehole fluid temperature. The TTP-11 have a GO pin Feed-Through to allow negative-voltage powered tools to run in combination (for ex. Noise tools). Tool applications include: Finding cement top, locating fluid entry, identifying gas leaks, and injection zones. The TTP-11 tool measures fluid temperature by measuring the resistance of a platinum RTD (Resistance Temperature Detector) inside a pressure probe. The measurements from the low mass probe results in high resolution data with fast temperature response.
TCP-10 | 1-11/16″ Temperature CCL Tool

TCP-10 | 1-11/16" Temperature CCL Tool

The 1-11/16” Temperature/CCL Pulse (TCP-10) is a muti-sensor integrated tool to measure borehole Temperature and locate Casing Collars.  The platinum RTD (Resistance Temperature Detector) provides high resolution temperature readings with fast response. Tool applications include: Depth correlation - Finding cement top - Locating fluid entry - Identifying gas leaks and injection zones
GRT-10 | 1-11/16″ Gamma Ray Pulse Tool

GRT-10 | 1-11/16" Gamma Ray Pulse Tool

The DSS 1-11/16” Gamma Ray pulse Tool (GRT-10) measures the gamma radiation level of the formation derived from natural isotopes. It can be used as a depth correlation device between cased and open holes. This tool is comprised of a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The GRT-10 outputs 25 µs pulses in response to gamma radiation within the well.
GRC-10 | 1-11/16″ Gamma Ray CCL Tool

GRC-10 | 1-11/16" Gamma Ray CCL Tool

The DSS GRC-10 Is a 1 11/16” multi purpose pulse Tool (GRC). This tool includes a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. It can be used as a depth correlation device between cased and open holes. It also includes a magnetic device that detects the changes in metal mass of a casing collar as it moves through well casing. The detector is a coil mounted between two opposing magnets. As the tool passes a collar; the magnet flux around the two magnets disturbed and induces a low frequency voltage.
GRT-20 | 2-3/4” Gamma Ray Pulse Tool

GRT-20 | 2-3/4” Gamma Ray Pulse Tool

The DSS 2 3/4” Gamma Ray pulse Tool (GRT) measures the gamma radiation level of the formation derived from natural isotopes. It can be used as a depth correlation device between cased and open holes. This tool is comprised of a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The GRT-01 outputs 25 µs pulses in response to gamma radiation within the well.
CCL-20 | 2-3/4” Casing Collar Locator

CCL-20 | 2-3/4” Casing Collar Locator

This logging CCL tool is a magnetic device that detects the changes in metal mass of a casing collar as it moves through well casing. The detector is a coil mounted between two opposing magnets. As the tool passes a collar; the magnet flux around the two magnets disturbed and induces a low frequency voltage. The voltage difference in the coil is amplified onto the wireline