CCL-20 | 2-3/4” Casing Collar Locator

This logging CCL tool is a magnetic device that detects the changes in metal mass of a casing collar as it moves through well casing. The detector is a coil mounted between two opposing magnets. As the tool passes a collar; the magnet flux around the two magnets disturbed and induces a low frequency voltage. The voltage difference in the coil is amplified onto the wireline

Share on linkedin
Share on facebook

Applications

Depth correlation
Determine casing collar location
Location of tubing and casing damage

Features

Rated for high-temperature and high-pressure environments
Reverse voltage protection
Compatible with most surface systems
Runs on all standard wirelines
Can be run by itself, or combined with most analog tools
Electronic design verified for 1 hour operation at 415°F to ensure reliability
Sour service compatible materials
Easy to service and maintain

Specifications

Tool Operating Voltage +90 to +150 VDC Tool Length (make-up) 34.92 cm (13.75 in)
Tool Operating Current 12 to15 mA Tool Length (shipping) 39.37 cm (15.5 in)
Current Swing ± 10 mA Tool Weight 9.4 Kg (20.5 Lb)
Max. Pressure 172.4 Mpa (25 000 PSI) Measurement Point from Top of Tool
Max. Temperature 204°C (400°F) Borehole Fluids Oil – Fresh Water – Brine
Housing material BeCu Top End Connector Contact Socket Go Female
Tool Diameter – OD 69.85 mm(2-3/4 in) Bottom End Connector Contact Pin Go Male

 

I'd like to get a quote on CCL-20 | 2-3/4” Casing Collar Locator

Products related to CCL-20 | 2-3/4” Casing Collar Locator

TTP-11 | 1-11/16″ Temperature Pulse Tool

TTP-11 | 1-11/16" Temperature Pulse Tool

The 1-11/16” Temperature Pulse Tool (TTP-11) measures borehole fluid temperature. The TTP-11 have a GO pin Feed-Through to allow negative-voltage powered tools to run in combination (for ex. Noise tools). Tool applications include: Finding cement top, locating fluid entry, identifying gas leaks, and injection zones. The TTP-11 tool measures fluid temperature by measuring the resistance of a platinum RTD (Resistance Temperature Detector) inside a pressure probe. The measurements from the low mass probe results in high resolution data with fast temperature response.
TCP-10 | 1-11/16″ Temperature CCL Tool

TCP-10 | 1-11/16" Temperature CCL Tool

The 1-11/16” Temperature/CCL Pulse (TCP-10) is a muti-sensor integrated tool to measure borehole Temperature and locate Casing Collars.  The platinum RTD (Resistance Temperature Detector) provides high resolution temperature readings with fast response. Tool applications include: Depth correlation - Finding cement top - Locating fluid entry - Identifying gas leaks and injection zones
GRT-10 | 1-11/16″ Gamma Ray Pulse Tool

GRT-10 | 1-11/16" Gamma Ray Pulse Tool

The DSS 1-11/16” Gamma Ray pulse Tool (GRT-10) measures the gamma radiation level of the formation derived from natural isotopes. It can be used as a depth correlation device between cased and open holes. This tool is comprised of a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The GRT-10 outputs 25 µs pulses in response to gamma radiation within the well.
GRC-10 | 1-11/16″ Gamma Ray CCL Tool

GRC-10 | 1-11/16" Gamma Ray CCL Tool

The DSS GRC-10 Is a 1 11/16” multi purpose pulse Tool (GRC). This tool includes a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. It can be used as a depth correlation device between cased and open holes. It also includes a magnetic device that detects the changes in metal mass of a casing collar as it moves through well casing. The detector is a coil mounted between two opposing magnets. As the tool passes a collar; the magnet flux around the two magnets disturbed and induces a low frequency voltage.
GTC-11 | 1-11/16” Gamma Ray Temperature CCL Tool with Negative Feed Through

GTC-11 | 1-11/16” Gamma Ray Temperature CCL Tool with Negative Feed Through

The 1-11/16” Gamma Ray/Temperature/CCL tool (GTC-11) is a multi-sensor correlation and well monitoring tool. The GTC-11 includes a Platinum RTD sensor which provides high-resolution wellbore temperature data with fast response. The GTC-11 also has a GR detector (scintillation crystal and a rugged photomultiplier tube) to measure the formation natural GR activity. The tool has a magnetic sesnor to locate casing collars, CCL. The GTC-11 model has feed-through wiring to a standard GO connector on the bottom so when a negative voltage is applied at the cable head, the negative voltage is routed directly to bottom GO connector. This function allows a Noise tool, or any other negative-powered tool, to be used below the GTC-11.
GRT-20 | 2-3/4” Gamma Ray Pulse Tool

GRT-20 | 2-3/4” Gamma Ray Pulse Tool

The DSS 2 3/4” Gamma Ray pulse Tool (GRT) measures the gamma radiation level of the formation derived from natural isotopes. It can be used as a depth correlation device between cased and open holes. This tool is comprised of a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The GRT-01 outputs 25 µs pulses in response to gamma radiation within the well.